- Home
- >
- Tender
- >
- Madhya Pradesh Tender
- >
- Department of Military Engineer Services
- >
NTID 46048563
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRepair Maintenance Of Ac Dee in MHOW - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Repair Maintenance Of Ac Dee" in MHOW, India.
Military Engineer Services
MHOW, Madhya Pradesh, India
NTID 46048563
- Opening Date : Fri 7th August, 2026
- Closing Date : Wed 5th August, 2026
- ₹ 1000000.00
- NTID 46048563
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
20000.00 -
Document Cost
500.00 -
Estimated Cost
1000000.00
BOQ Items Total Items : 73 | Total Qty : 1211
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Carrying out comprehensive maintenance of window and split type air conditioners, refrigerators, deep freezers, desert coolers and water purifiers (RO/UV/UF type) including periodic servicing, preventive maintenance and attending breakdown complaints. The work includes dismantling wherever required, thorough cleaning of filters, evaporator and condenser coils using suitable chemical solution, cleaning of blower, fan motor, drain tray and drain pipe including removal of choke and flushing. Checking, testing and servicing of compressors, fan motors, blowers, thermostats, relays, overload protectors, contactors, PCB, selector switches, SMPS, solenoid valves, RO pumps, UV lamps, membranes and allied components. Attending faults such as inadequate cooling, noise, vibration, water leakage, gas leakage etc., including leak detection using nitrogen pressure, rectification by brazing of copper tubing, vacuuming and charging of suitable refrigerant gas and topping up as required. Including replacement of minor spares such as capacitors, thermostats, relays, wiring, lugs, drain pipes, insulation tape, fasteners, rubber parts, filter candles, carbon filters and other consumables required for proper functioning of equipment. For water purifiers, work includes cleaning/ flushing of complete system, checking and servicing of RO membrane, UV lamp, sediment and carbon filters, pipelines, storage tank, ensuring proper purification and discharge. Checking of complete electrical system including wiring, earthing, insulation, tightening of terminals and ensuring safe operation. Including dismantling and refixing of units (if required during maintenance), complete testing, commissioning and handing over in satisfactory working condition, complete all as specified and directed. | 225 | Each Job |
| 2 | Srl Item No 1.00 Note:- (a) The work shall be carried out by a fully trained, experienced and technically qualified team. Technicians deployed must be authorised/ certified by OEM or having valid technical certification and adequate experience in handling HVAC and refrigeration equipment. Team shall be provided daily by the contractor for complaints. (b) Rep of the contractor will remain present in complaint cell & responsible for receiving & attending the complaints from 0800 Hrs to 1600 Hrs daily, the time of lodging the complaint. (c) Cost of minor stores such as screws, clamps, insulation tapes, nuts/ bolts, nails of required size etc shall be deemed included in the quoted rate. (d) Complaints where complete replacement of circuit/ point wiring is required shall be measured under relevent item of this schedule. (e) Complaint must be attended within 24 hours. A penality shall be imposed if delay beyond 24 hrs @ ₹ 200 per day per equipments. (f) Non-Performance; If any equipment remains non-functional for more than 72 hours, a penalty of @ ₹ 500 per day per equipment shall be levied. | ||
| 3 | S&F in repair sealed compressor unit for any make and any type of Air Conditioner, window/ Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressor unit by connecting suction and discharge lines with gas welding/ brazing work including checking the leakeage in the system and tightening foundation nuts & bolts etc. complete all as specified and directed. Note:- Gas charging will be measured and paid for separately in respective item of this schedule. | 10 | Each Job |
| 4 | All as per Srl item No. 3.00 here-in-before but for air conditioner capacity 2 TR, complete all as specified and directed. | 8 | Each |
| 5 | All as per Srl item No. 3.00 here-in-before but for air conditioner split type, 3 ton capacity, complete all as specified and directed. | 1 | Each |
Purchase Access To Download Selected Documents