- Home
- >
- Tender
- >
- Uttarakhand Tender
- >
- Department of Military Engineer Services
- >
NTID 47127254
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRepair And Replacement Of Floo in Raiwala - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Repair And Replacement Of Floo" in Raiwala, India.
Military Engineer Services
Raiwala, Uttarakhand, India
NTID 47127254
- Opening Date : Thu 5th November, 2026
- Closing Date : Tue 3rd November, 2026
- ₹ 950000.00
- NTID 47127254
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
BOQ Items Total Items : 83 | Total Qty : 8953.5
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land.Complete all as specified and directed | cum | |
| 2 | M/L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation complete all as specified and directed. | cum | |
| 3 | Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge . Note : Ponding test after water proofing coating willl be done for ponding for 48 Hrs . | Sqm | |
| 4 | M&L fir 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified reapir mortar complete all as specified and directed. | Sqm | |
| 5 | M/L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge | 3 | RM |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054