- Home
- >
- Tender
- >
- Tamil Nadu Tender
- >
- Department of Public Works Department
- >
NTID 47276596
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRenewal Of Panel Board And Pow in Tiruvarur - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Renewal Of Panel Board And Pow" in Tiruvarur, India.
Public Works Department
Tiruvarur, Tamil Nadu, India
NTID 47276596
- Opening Date : Thu 5th November, 2026
- Closing Date : Thu 5th November, 2026
- ₹ 200000.00
- NTID 47276596
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
2000.00 -
Document Cost
Refer Documents -
Estimated Cost
200000.00
BOQ Items Total Items : 9 | Total Qty : 138
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Renewal by supply and run of 4 of 6sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6sq.mm copper wire with painting of suitable colour. | 90 | Mtrs |
| 2 | Renewal by supply and fixing of 125A Capacity dust and vermin proof cubic panel board size of 0.90m (H) 1.80 (W) 0.30 (D) made up of 16SWG sheet steel for outer body and stiffness and doors switches supports respectively and with supply and fixing of the following cubical mounting switches with centre bus bar chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in IS specifications. 1. 125A TPN switch disconnector fuse unit interior only with HRC fuses double break (L&T / Siemens make) - 1No. 2. 100A TPN switch disconnector fuse unit interior only with HRC fuses double break (L&T/ Siemens make) - 1No. 3. 63A TPN switch disconnector fuse unit interior only with HRC fuses double break (L&T / Siemens make) - 4Nos. 4. 32A TPN switch disconnector fuse unit interior only with HRC fuses double break (L&T / Siemens make) - 1No. A separate chamber on top of one side should be built with one set of LED pilot lamps set with fuse base, top with 10A HRC link for 3 phases (Siemens) the bus will have 3 Nos. of 25x6mm bus for phase and 1No. neutral and 2 Nos. 25 x 3 mm earth bus for must be in all round the panel to provide double earth connection to the cubical switches cable glandscable adopter box etc. bus should be mounted on synthetic enamel compound bus supports at equal interval as per IS specifications. A switches with should be connected to the bus with same size of 50x6 mm fixed copper flat 400A 25x6 mm fixed copper flat 250A switch, 100A switch,63A switch should be connected to the bus by 12.5x3mm fixed copper flat. The switch should be separated by 6mm thick hylum sheet separators and properly (Double) earthen as per IE rules, CEIG specification. The panel should be painted with two coats of high quality enamel paint over one coat of red oxide primer, the cable size capacity of switch location etc. should be marked with white paint and 2Nos. metallic danger board affixed completed with mounting on base channel supports. | 1 | No |
| 3 | Renewal by supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double brEak on suitable angle iron frame work with MS cable entry boxes with Earth connection only. | 1 | No |
| 4 | Renewal by supply and clamping of 3½ x 95sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. | 30 | Mtrs |
| 5 | Renewal by supply and fixing of 100W flood light suitable angle support on wall with connection. | 1 | No |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054