- Home
- >
- Tender
- >
- Maharashtra Tender
- >
- Department of Bhiwandi Nizampur City Municipal Corporation
- >
NTID 39852759
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowProvidingpassanger Stretcher L in Bhiwandi - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Providingpassanger Stretcher L" in Bhiwandi, India.
Bhiwandi Nizampur City Municipal Corporation
Bhiwandi, Maharashtra, India
NTID 39852759
- Opening Date : Fri 4th April, 2025
- Closing Date : Thu 3rd April, 2025
- ₹ 5468592.00
- NTID 39852759
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
54686.00 -
Document Cost
590.00 -
Estimated Cost
5468592.00
BOQ Items Total Items : 7 | Total Qty : 84
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Providing Passanger Stretcher Lift at BGP Hospital Mandai Bhiwandi. | ||
| 2 | SITC of Electric Traction Passenger cum Stretcher Hospital Lift with Rated capacity 20 Passenger 1360Kg Floors G 1 floor 2 Stops 2 Landings Travel 3 to 4.2 mtrs Location of Lift Machine MR MRL Rated speed 1.0mps VS Car Landing door clear opening of 1100 1200 mm wide x 2000 mm high Clear Car size of ......mm wide x ......mm deep x 2250mm high Lift shaft available having clear size of ......mm wide x ......mm deep ......mm Pit depth mm Overhead. Doors type COPO TOPO Doors with frame made from SS 304 grade solid non cladded sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves frames The lift doors shall have minimum 1 hour fire rating with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory Lift car enclosure made from SS 304 grade solid non cladded sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower fan for ventilation and SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code and luminous indicator around button with FPI scrolling UP DN LED indicator and with without attendant key switch OWD with audio visual alarm VAS in Marathi Hindi and English with intercom system with telephone instrument in Lift car LMR and FCC ground floor. LOP with SS face plate having recess surface push button box for all landings with scrolling UP DN LED indicator having metallic push buttons with Braille code and luminous indicator around button with CPI Lift car arrival and next travel direction audio visual indication at all landings. Lift controller based on microprocessor PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open close operation from COP etc. The system can record information for minimum 30 latest faults with real time clock management and handheld keypad with LCD screen for view and setting of parameters The control panel duly wired with proper size and strength copper wire for power and control circuit with provision for addition of floor control card and allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car and in LMR inside lift shaft top aimed on Lift machinery and controller with NVR kept in LMR FCC with HDR data backup for min. 90 days with min. 20 FHD TV monitor to be kept in FCC LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts hr with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor shaft walls complete with main diverter traction sheaves suspension wire ropes belts of adequate size and strength. Other mechanical parts such as T section adequate size guide rails for car and counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it s accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required and scaffolding for erecting guide rails providing and fixing steel girders RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. General Job includes entire procedure of obtaining all necessary erection permissions and License to Work the Lift from Electrical Inspector Lifts with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. | 2.00 | Nos |
| 3 | For Lift having 1100mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid non cladded landing door Two panel this includes all necessary accessories like LOP s with UP DN buttons arrows indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes belts OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. ADD on A 5 pg no.274. B G 2 per lift 4 stop 4 opening for 2 lift | 4.00 | Nos |
| 4 | For Full Collective control system for Lift travelling above First floor and up to Sixth floor ADD on B 1 pg no.276. B G 2 per lift 4 stop 4 opening for 2 lift | 4.00 | Nos |
| 5 | For additional 2MP Camera along with necessary accessories at Home Landing add as given. ADD on C pg no.276. | 2.00 | Each |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054