- Home
- >
- Tender
- >
- Rajasthan Tender
- >
- Department of Nuclear Fuel Complex
- >
NTID 43182955
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowPreventive Maintenance Of Vent in Chittorgarh - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Preventive Maintenance Of Vent" in Chittorgarh, India.
Nuclear Fuel Complex
Chittorgarh, Rajasthan, India
NTID 43182955
- Opening Date : Sat 27th December, 2025
- Closing Date : Fri 26th December, 2025
- ₹ 7735100.00
- NTID 43182955
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
154702.00 -
Document Cost
Refer Documents -
Estimated Cost
7735100.00
BOQ Items Total Items : 18 | Total Qty : 2344
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Preventive Maintenance(PM) of Centrifugal Blowers : Frequency : Quarterly (once in 3 months) PM works involves tbe following: a) Ensure Drive V-Belts tension (if reqd, adjust motor) b) Replace damaged V-belts c) Ensure coupling in good condition (if reqd, replace) d) Grease the Brearings e) Ensure Flexible joints in good condition (if reqd, replace) f) Ensure Belt guard in good position (if reqd, reset) g) Grease Damper bearings h) Ensure all fasteners are in complete fastened conditon (if reqd, fasten) i) Ensure the actuator connections in order (if reqd, refix) j) Report, if any abnormality in functioning Note : PM shall be performed for installed 184 qty per quater. | ||
| 2 | Blowers upto 55 KW capacity | 480 | Nos |
| 3 | Blowers from 56 KW to 350 KW capacity | 256 | Nos |
| 4 | Preventive Maintenance(PM) of Horizontal coupled Centrifugal Pumps : Frequency : Quarterly (once in 3 months) PM works involves tbe following: a) Makeup oil in bearing chamber b) Ensure coupling in good condition (if reqd, replace) c) Ensure coupling guard in position (if reqd, adjust & fasten) d) Ensure NO water leakage (if reqd, rectify) e) Remove Strainer clean & re-fit f) Ensure all Nut Bolts are fastened (if reqd, fasten) g) Drain hydrocyclone till sediment is bleeded out h) Report if any abnormality is observed Note : PM shall be performed for installed 32 qty per quater. | ||
| 5 | Pumps upto 20 KW capacity | 108 | Nos |