- Home
- >
- Tender
- >
- Uttar Pradesh Tender
- >
- Department of Public Works Department
- >
NTID 47277563
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowJanpad Muzaffarnagar Me Lok Ni in Muzaffarnagar - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Janpad Muzaffarnagar Me Lok Ni" in Muzaffarnagar, India.
Public Works Department
Muzaffarnagar, Uttar Pradesh, India
NTID 47277563
- Opening Date : Sat 7th November, 2026
- Closing Date : Sat 7th November, 2026
- ₹ 1054000.00
- NTID 47277563
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
106000.00 -
Document Cost
766.00 -
Estimated Cost
1054000.00
BOQ Items Total Items : 8 | Total Qty : 23
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Lok Nirman Vibhag ke antargat shaaskiya bhavno (karyalay adhishasi abhiyanta prantiya khand Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya. | ||
| 2 | SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years). | 6 | KWp |
| 3 | Lok Nirman Vibhag ke antargat shaaskiya bhavno (Nireekshan Bhavan Jaansath Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya. | ||
| 4 | SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years). | 3 | KWp |
| 5 | Lok Nirman Vibhag ke antargat shaaskiya bhavno (Navnirmit Nireekshan Bhavan Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054