Military Engineer Services
Mumbai, Maharashtra, India
NTID 43935942
- Opening Date : Wed 4th March, 2026
- Closing Date : Mon 2nd March, 2026
- ₹ 3500000.00
- NTID 43935942
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
70000.00 -
Document Cost
500.00 -
Estimated Cost
3500000.00
BOQ Items Total Items : 30 | Total Qty : 19063
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | M&L for Electrical safety energy audit of Main Recieving Station, Electric sub stations, HT/LT Switch gears, LT panel board and feeder piller boxes, HT/LT cable Net working system, water supply pumping installations and Air Conditioning Plants based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details : (i) conducting survey of electric Sub stations -10 Nos. (ii) conducting survey of Pump houses -17 Nos. (iii) On ground site check of all LT Panel boards and feeder piller boxes. (iv) Checking of earth resistance , Load balancing. (v) Checking of loose connections. (vi) Testing of APFC Panels and power factor Identification and devlopment of energy conservation opportunities.(ENCON) (vii) Comparision and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture. | 1.00 | Each Job |
| 2 | M & L for Electrical safety energy audit of LIFT Installations and Fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details : (i) conducting survey of all high rise buildings from G+6 and above - 12 Nos. (ii) conducting survey of all high rise buildings upto G+6 - 27 Nos. (iii) On ground site check of all control Panel boards and fie panel boards, meter panels and DBs. (iv) Checking of earth resistance in meter Room, Load balancing. (v) Checking of loose connections. (vi) Identification and development of energy conservation opportunities.(ENCON). (vii) Comparision and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture. Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY (ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and Statae Govt. (iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | 1.00 | Each Job |
| 3 | M & L for Electrical safety energy audit of buildings and fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M (W) Colaba, Mumbai as per following details : (i) conducting survey of all Machine Rooms of lift -26 Nos. (ii) conducting survey of fire fighting Pump houses -5 Nos. (iii) On ground site check of all control Panel boards and fire panel boards. (iv) Checking of earth resistance in Machine Room , Load balancing. (v) Checking of loose connections. (vi) Identification and development of energy conservation opportunities.(ENCON). (vii) Comparision and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture. Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY. (ii) Energy audit service provider must be having minimum experience of 10 years with Central Govt and State Govt. (iii) Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter, magger etc. | 1.00 | Each Job |
| 4 | Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 120 Sqmm x 3.5 core including disconnecting /getting out old unserviceable cable, complete all as specified and directed. | 50.00 | RM |
| 5 | All as per sl item No. 4 but for cable size 95 Sqmm x 3.5 Core. | 30.00 | RM |