Inquiry NowElectrical Wiring For Upcoming in Sultanpur - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Electrical Wiring For Upcoming" in Sultanpur, India.
BABASAHEB BHIMRAO AMBEDKAR UNIVERSITY
Sultanpur, Uttar Pradesh, India
NTID 46612250
- Opening Date : Tue 15th September, 2026
- Closing Date : Mon 14th September, 2026
- ₹ 318051.00
- NTID 46612250
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
7951.00 -
Document Cost
Refer Documents -
Estimated Cost
318051.00
BOQ Items Total Items : 10 | Total Qty : 555
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (DSR 2025 - 1.14.11) | 65 | Metre |
| 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) (DSR 2025 - 11.1.33) | 2 | Each |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (DSR 2025 - 1.14.10) | 10 | Metre |
| 4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door (DSR 2025 - 2.3.1) | 1 | Each |
| 5 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A (DSR 2025 - 2.15.3) | 2 | Each |