- Home
- >
- Tender
- >
- Kerala Tender
- >
- Department of Kerala State Council for Science Technology And Environment
- >
NTID 42515388
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Construction Of in Thiruvananthapuram - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Construction Of " in Thiruvananthapuram, India.
Kerala State Council for Science Technology And Environment
Thiruvananthapuram, Kerala, India
NTID 42515388
- Opening Date : Mon 29th December, 2025
- Closing Date : Fri 26th December, 2025
- ₹ 2619067819.00
- NTID 42515388
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
500000.00 -
Document Cost
17700.00 -
Estimated Cost
2619067819.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Corrigendum 6 | Date |
| 2 | Corrigendum 5 | Other |
| 3 | Addendum - 3 | Technical Bid |
BOQ Items Total Items : 12 | Total Qty : 12
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Constructing, Finishing and making the Admin Building functional in all respect : Earth Work Cutting and Levelling in all kinds of Soil, RCC framed structure (Service Floor + G +2 + Mumty) with filler walls of Autoclaved aerated cement blocks (AAC blocks), including internal water supply, Internal Sanitary installations, Providing Oil and Grease Chamber of the Sewage Line to the STP, RCC Retaining Wall part of Building Structure, Terrace Water Tanks, Plinth Protection with following MEP works of entire building (a) Internal Electrical Works : Sub-Main, Circuit Point Wiring, and Power Point Wiring, Fittings, Fans, SDBs, MCB-DBs with accessories, Main Panel, Floor-wise Panel, Sub Panel, Cable Trays, Cabling, earthing, etc. (metering shall be integrated with BMS). (b) Lightning Protection Works including Earthing (c) Lifts: two nos of Machine Room Less (MRL) Lifts of 8 passengers capacity with 900 mm door, integrated with BMS, (d) Fire alarm: (i) Addressable type automatic fire alarm system with 2 loop main control panel having built-in battery, display system, cards etc. for integrating with BMS, (ii) Accessories like heat detectors for kitchen area/ multi-sensor type detector for other areas having isolation facility , Manual Call box etc. (iii) Digital Type Voice Type Evacuation System with built in Amplifier and other accessories like microphone, speakers, etc. (e) Firefighting : (i) Connecting the riser fire pump at terrace, fire station cabinet with hydrant valve, first aid hose, canvas hose, branch pipe etc. (ii) Portable type Fire extinguishers (iii) Luminous Type Signage powered with UPS. (f) CCTV : Doom / Bullet Type Camera useful for indoor / outdoor type connected with a CAT 6A cable, network rack and switch, display system and Network recording System (NVR) with 10 TB Hardisk. (g) Low Side HVAC : (i) Cold Water Piping from the existing Ring Main to AHUs (Double skin, Eurovent/BIS certified, insulated, backward curved aerofoil plug fans with VFD, multi-stage filters, UV lamps, IE3 motors, vibration isolation, weather-proof VFD, BMS compatible, sound 65 dBA, coil pressure drop 7 PSIG), VAV (Pressure-independent, with actuators, controllers, thermostat, actuator, control cables, flexible ducts, GI conduits), Duct for supply and return air, Fire Damper (Motorised, spring-return (auto close on power failure/fire signal), integrated with fire panel) , Grills, VAV and thermostat control for each room, Insulated Drainage Pipe, providing 2 nos. of 2 TR inverter split type AC (5 star rated) operated with timer for UPS room as additional AC system. (ii) Acoustic Treatment : Wall and Ceiling of AHU rooms and Ceiling of Top Floor of AC area by providing Aluminium Strip Framework of 1m x 1m, 50mm thick 32 Kg/m3 Glass Wool with RP tissue paper and Aluminium Perforated Sheet on outer surface, ventilation system for all corridors and bathrooms (h) UPS: 90KVA modular type UPS having 30 minutes backup (frame size of modular UPS can have more capacity) for essential services and fire alarm. (i) Networking & IP PBX: (i) Providing entire passive and active components such as suitable size rack with Patch Panel, switches, Cable tray, CAT 6A Cabling rack to RJ 45 outlet, 12 Core OFC Cable from Main Rack to Sub Rack (including commissioning BMS and network for computers, CCTV, IP phone etc.) including DDC panel & connected all works for entire network system such as commissioning BMS and different network system for BMS, etc. (ii) IP PBX with SIP trunk technology suitable for not less than 100 IP phone including cabling and commissioning (Make - Matrix, Seimens, Astrix) all complete. The building shall be constructed as per the approved architectural, structural and MEP drawings, Brief/ Technical specification and General specifications etc. as included in the tender document. No. of Blocks: One. (B Block) | 1 | Each job (Lump sum) |
| 2 | Constructing ,Finishing and making the R & D Block 1 functional in all respect : Earth Work Cutting and Levelling in all kinds of Soil, RCC framed structure (Service Floor + LG + G + 3 + Mumty) with filler walls of Autoclaved aerated cement blocks (AAC blocks), including internal water supply from sump to the Terrace Tank and further distribution lines, fittings as per the building MEP drawings and Sanitary installations and pipe lines, Providing Oil and Grease Chamber of the Sewage Line to the STP, RCC Retaining Wall part of Building Structure, Sump with Pumping System, RCC Water Tanks, Plinth Protection with following internal MEP works of entire building (a) Internal Electrical Works : Sub-Main, Circuit Point Wiring, and Power Point Wiring, Fittings, SDBs, MCB-DBs with accessories for common area and sample lab of 3 Module and one light point and fan hooks for other labs, Main Panel, sub-panels, compact type aluminium bus bar with End Feed Box, Tap Off Units etc. as per SLD, Cable tray, Cabling, earthing etc. (metering, energy meter, having RS Port need to be integrated with BMS for all sample lab and provision for other labs) etc. (b) Lightning Protection Works including Earthing (c) Lifts : Three nos of Machine Room Less(MRL) Lifts of 20 passengers capacity and one number of Good Lift (MRL) of 3 Ton Capacity integrated with BMS, (d) Fire alarm : (i) Addressable type automatic fire alarm system with 8 loop main control panel having built-in battery, display system, cards etc. for integrating with BMS (for sample lab additional detector in between slab and false ceiling need to be provided and other labs, provisions for providing additional detector and if the occupying agency need to provide false ceiling), (ii) Accessories like heat detectors for kitchen area / multi-sensor type other areas having isolation facility , Manual Call box etc (iii) Digital Type Voice Type Evacuation System with built in Amplifier and other accessories like microphone, speakers, etc. (e) Firefighting : (i) Pipeline inside the building, connecting the riser, fire pump at terrace, fire station cabinets with hydrant valves, first aid hoses, canvas hoses, branch pipes etc. (ii) Portable type Fire extinguishers (iii) Luminous Type Signage powered with UPS. (f) Automatic Sprinkler System : Pipeline inside the building, connecting riser pipe from the existing ring main, drainage piping providing sprinkler system entire building (for sample lab additional sprinkler in between slab and false ceiling need to be provided and for other labs provisions for providing additional sprinkler if the occupying agency need to provide false ceiling, in these labs flexible connecting pipe of suitable length shall be used for connecting sprinkler to pipeline by considering false ceiling) (g) CCTV : Doom / Bullet Type Camera useful for indoor and outdoor type connected with a CAT 6A cable, network rack and switch, display system and Network recording System (NVR) with 10 TB Hardisk. (h) Low Side HVAC : (i) Cold Water Piping (Pre Insulated) in the building including tapping the pipelines from the existing Ring Main, Ceiling Suspended type AHUs (Double skin, Eurovent/BIS certified, insulated, backward curved aerofoil plug fans with VFD, multi-stage filters, UV lamps, IE3 motors, vibration isolation, weather-proof VFD, BMS compatible, sound 65 dBA, coil pressure drop 7 PSIG), VAV (Pressure-independent, with actuators, controllers, thermostat, actuator, control cables, flexible ducts, GI conduits), Duct for supply and return air, Grills, VAV and thermostat control, Insulated Drainage Pipe, etc. for sample lab (3 Module), UPS/Server Room and Fire Control/BMS Room (For all other labs, pipes shall be terminated inside the lab with pipe providing suitable type valves for metering and AHUs to be provided later date), providing 2 nos. of 2 TR inverter split type AC (5 star rated) operated with timer for UPS room as additional AC system. (ii) Metering : BTU meter integrated with BMS for main header line, sample lab (Ceiling Suspended AHU in other labs including metering will be in the scope of occupant) (i) Ventilation System in all corridors and bathrooms (j) Other Metering : Metering integrated with BMS shall be provided for normal water, RO Water, Vacuum, Compressed Air etc for sample lab (for other labs, metering will be in the scope of occupant). (k) UPS : 60KVA modular type UPS having 30 minutes backup (frame size of modular UPS can have more capacity) for essential services and fire alarm. (l) Networking: Providing entire passive and active components such as suitable size server, distribution rack & rack with Patch Panel, switches, Cable tray, CAT 6A Cabling rack to RJ 45 outlet, 12 Core OFC Cable from Main Rack to Sub Rack, 24 Core OFC cable from main entrance to the building in suitable size HDPE pipe for server (including commissioning server, server cooling system, racks, BMS and network for computers, CCTV, IP phone etc. for the entire campus) including DDC panel & connected all works for entire network system such as commissioning BMS and different network system for BMS, etc. all complete. The building shall be constructed as per the approved architectural, structural and MEP drawings, brief / technical specification and General specifications etc. as included in the tender document. No. of Blocks: One (C1) | 1 | Each job (Lump sum) |
| 3 | Constructing ,Finishing and making the R & D Block 2 functional in all respect : Earth Work Cutting and Levelling in all kinds of Soil, RCC framed structure (Service Floor + LG + G + 3 + Mumty) with filler walls of Autoclaved aerated cement blocks (AAC blocks), including internal water supply from sump to the Terrace Tank and further distribution lines, fittings as per the building MEP drawings and Sanitary installations and pipe lines, Providing Oil and Grease Chamber of the Sewage Line to the STP, RCC Retaining Wall part of Building Structure, Sump with Pumping System, RCC Water Tanks, Plinth Protection with following internal MEP works of entire building (a) Internal Electrical Works : Sub-Main, Circuit Point Wiring, and Power Point Wiring, Fittings, SDBs, MCB-DBs with accessories for common area and sample labs of 2 Module & 1 module and one light point and fan hooks for other labs, Main Panel, sub-panels , compact type aluminium bus bar with End Feed Box, Tap Off Units etc. as per SLD, Cable tray, Cabling, earthing etc. (metering, energy meter, having RS Port need to be integrated with BMS for all sample lab and provision for other labs) etc. (b) Lightning Protection Works including Earthing (c) Lifts : Three nos of Machine Room Less(MRL) Lifts of 20 passengers capacity and one number of Good Lift (MRL) of 3 Ton Capacity integrated with BMS, (d) Fire alarm : (i) Addressable type automatic fire alarm system with 8 loop main control panel having built-in battery, display system, cards etc. for integrating with BMS (for sample labs additional detector in between slab and false ceiling need to be provided and other labs, provisions for providing additional detector and if the occupying agency need to provide false ceiling), (ii) Accessories like heat detectors for kitchen area / multi-sensor type other areas having isolation facility , Manual Call box etc (iii) Digital Type Voice Type Evacuation System with built in Amplifier and other accessories like microphone, speakers, etc. (e) Firefighting : (i) Pipeline inside the building, connecting the riser, fire pump at terrace, fire station cabinets with hydrant valves, first aid hoses, canvas hoses, branch pipes etc. (ii) Portable type Fire extinguishers (iii) Luminous Type Signage powered with UPS. (f) Automatic Sprinkler System : Pipeline inside the building, connecting riser pipe from the existing ring main, drainage piping providing sprinkler system entire building (for sample labs additional sprinkler in between slab and false ceiling need to be provided and for other labs provisions for providing additional sprinkler if the occupying agency need to provide false ceiling, in these labs flexible connecting pipe of suitable length shall be used for connecting sprinkler to pipeline by considering false ceiling) (g) CCTV : Doom / Bullet Type Camera useful for indoor and outdoor type connected with a CAT 6A cable, network rack and switch, display system and Network recording System (NVR) with 10 TB Hardisk. (h) Low Side HVAC : (i) Cold Water Piping (Pre Insulated) in the building including tapping the pipelines from the existing Ring Main, Ceiling Suspended type AHUs (Double skin, Eurovent/BIS certified, insulated, backward curved aerofoil plug fans with VFD, multi-stage filters, UV lamps, IE3 motors, vibration isolation, weather-proof VFD, BMS compatible, sound 65 dBA, coil pressure drop 7 PSIG), VAV (Pressure-independent, with actuators, controllers, thermostat, actuator, control cables, flexible ducts, GI conduits), Duct for supply and return air, Grills, VAV and thermostat control, Insulated Drainage Pipe, etc. for each sample labs (2 Module and 1 Module), UPS/Server Room and Fire Control/BMS Room (For all other labs, pipes shall be terminated inside the lab with pipe providing suitable type valves for metering and AHUs to be provided later date), providing 2 nos. of 2 TR inverter split type AC (5 star rated) operated with timer for UPS room as additional AC system. (ii) Metering: BTU meter integrated with BMS for main header line, all sample labs (Ceiling Suspended AHU in other labs including metering will be in the scope of occupant) (i) Ventilation System in all corridors and bathrooms (j) Other Metering : Metering integrated with BMS shall be provided for normal water, RO Water, Vacuum, Compressed Air etc for sample labs (for other labs, metering will be in the scope of occupant). (k) UPS : 60KVA modular type UPS having 30 minutes backup (frame size of modular UPS can have more capacity) for essential services and fire alarm. (l) Networking: Providing entire passive and active components such as suitable size rack with Patch Panel, switches, Cable tray, CAT 6A Cabling rack to RJ 45 outlet, 12 Core OFC Cable from Main Rack to Sub Rack (including commissioning BMS and network for computers, CCTV, IP phone etc.) including DDC panel & connected all works for entire network system such as commissioning BMS and different network system for BMS, etc. all complete. The building shall be constructed as per the approved architectural, structural and MEP drawings, brief / technical specification and General specifications etc. as included in the tender document. No. of Blocks: One. (C2) | 1 | Each job (Lump sum) |
| 4 | Constructing ,Finishing and making the Residence (Studio Block) functional in all respect : Earth Work Cutting and Levelling in all kinds of Soil, RCC framed structure (Service Floor + G+6 + Mumty) with filler walls of Autoclaved aerated cement blocks (AAC blocks), including internal water supply from sump to the Terrace Tank and further distribution lines, fittings as per the building MEP drawings and Sanitary installations and pipe lines, Providing Oil and Grease Chamber of the Sewage Line to the STP, RCC Retaining Wall part of Building Structure, Sump with Pumping System, RCC Water Tanks, Plinth Protection with following internal MEP works of entire building (a) Internal Electrical Works : Sub-Main, Circuit Point Wiring, and Power Point Wiring, Fittings, Fans, SDBs, MCB-DBs with accessories, Main Panel, Floor-wise Panels, Sub Panels, floor-wise metering panels (as per KSEB specifications), compact type busbar with accessories from main panel to Floor-wise metering panel, Cable Trays, Cabling, earthing, etc,. (b) Lightning Protection Works including Earthing (c) Lifts : one Machine Room Less (MRL) Lift of 13 passengers capacity, one Machine Room Less (MRL) Service Lift of 15 passenger capacity , (d) Fire alarm: Fire Alarm control panel with voice evacuation system, built-in battery, display system, cards, etc. (e) Firefighting: (i) Connecting the riser- fire pump at terrace, fire station cabinet with hydrant valve, first aid hose, canvas hose, branch pipe etc. (ii) Portable type Fire extinguishers (iii) Luminous Type Signage powered with UPS. (f) CCTV : Doom / Bullet Type Camera useful for indoor / outdoor type connected with a CAT 6A cable, network rack and switch, display system and Network recording System (NVR) with 10 TB Hardisk. (g) UPS: 1 number 3KVA UPS having 30 minutes backup (Connected in Parallel) for essential services and fire alarm. (h) Networking: Providing entire passive and active components such as suitable size rack with Patch Panel, switches, Cable tray, CAT 6A Cabling rack to RJ 45 outlet, 12 Core OFC Cable from Main Rack to Sub Rack (including commissioning BMS and network for computers, CCTV, IP phone etc.) including DDC panel & connected all works for entire network system such as commissioning BMS and different network system for BMS, etc. all complete. The building shall be constructed as per the approved architectural, structural and MEP drawings, Brief / Technical specification and General specifications etc. as included in the tender document. No. of Blocks: One. (D1 Block) | 1 | Each job (Lump sum) |
| 5 | Constructing ,Finishing and making the HT Panel Room (Ground Floor), LT Panel Room + AC Plant Room (G + 1 Floor) and Pump room for Diesel Storage Tank(Ground Floor) (including Fencing () functional in all respect : Earth Work Cutting and Levelling in all kinds of Soil, RCC framed structure with filler walls of Autoclaved aerated cement blocks (AAC blocks), including internal water supply and Sanitary installations, RCC Retaining Wall part of Building Structure, Water Tanks, Plinth Protection with following internal MEP works (a) Internal Electrical Works : Sub-Main, Circuit Point Wiring, and Power Point Wiring, Fittings, SDBs, MCB-DB (b) HT Panels & HT Cables: HT master meters - Panel 1 & 2, HT Panel - Panel 3& 5 (with Powerpack panel with batteries, booster charger, metering, etc.), HT meter - Panel 4, HT Panel of studio apartment - panel 63, 3C x 300 sq.mm 11 KV Cable from Master metering panels 1 & 2 to HT Panel, HT Panel 3 to metering panel 4, metering panel 4 to HT panel 5 and HT panel 63 of Studio apartment (c) Transformer : 2 nos, 11/0.433 KV ONAN type copper Wound - 2000 KVA OLTC outdoor transformer with all accessories for C1, C2 & Admin Block and 2 nos of 11/0.433 KV ONAN type copper Wound - 200 KVA Offload Tap Switch outdoor transformer with all accessories for Studio Apartment. (d) DG set : 5 nos 500 KVA DG set with acoustic enclosure in-buit diesel tank, Exhaust system with supporting structural works, piping, control cabling, etc. (e) LT Panel Outdooe/Indoor Bus Duct : Non Essential Panel - Panel 6, APFC Panels - Panel 7 & 8, Synchronizing panel - Panel 9, Essential Panel - Panel 10 for electrical distribution, Bus Duct from Transformer to Non Essential Panel, Non Essential panel to Synchronizing Panel, Synchronizing panel to Main Panel of Block C1, C2 and Main Panel of HVAC (Outdoor type Bus Duct with Canopy shall be fixed on a suitable size structure), common service panel - panel 44, fuel pump panel - panel 48, (f)Diesel Storage Tank : 25 KL capacity Main tank, 995 L capacity buffer tank, 2 nos of Pump, Automatic pumping system upto buffer tank, piping, gravity flow with control valve, buffer tank to the in-built diesel tank of DG set, piping, valves, flow-meter, overflow piping from in-built diesel tank to Main Storage tank.etc. required as per Explosive Department Norms. (g) Networking: Providing entire passive and active components such as suitable size rack with Patch Panel, switches, Cable tray, CAT 6A Cabling rack to RJ 45 outlet, 12 Core OFC Cable from Main Rack to Sub Rack (including commissioning BMS and network for computers, CCTV, IP phone etc.) including DDC panel & connected all works for entire network system such as commissioning BMS and different network system for BMS, etc. all complete. Note - The shop drawings of the bus duct, strcutural work for supporting outdoor Bus Bar, road crossin methods etc. need to be submitted for approval before execution No. of Blocks: Three. | 1 | Each job (Lump sum) |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054