- Home
- >
- Tender
- >
- Assam Tender
- >
- Department of BORDER SECURITY FORCE
- >
NTID 43923818
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCo Deficient Elements At Par W in Dhubri - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Co Deficient Elements At Par W" in Dhubri, India.
- Opening Date : Fri 20th February, 2026
- Closing Date : Wed 18th February, 2026
- ₹ 320870.00
- NTID 43923818
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
6417.00 -
Document Cost
Refer Documents -
Estimated Cost
320870.00
BOQ Items Total Items : 2 | Total Qty : 1006.96
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Soil investigation by boring up to 15.00 mtrs depth in all type of soil/rock strata at various location, performing SPT at 1.50 mtr interval as per IS 2131-1981. Collection of disturbed/ undisturbed soil samples of different strata of soil as per direction of Engineering-in-Charge. Visual and engineering classification sieve analysis and hydrometer analysis, liquid, plastic and shrinkage limits, specific gravity, chemical analysis and free swell index determination laboratory test to be performed on disturbed and undisturbed soil sample. Bulk density, moisture content, direct shear test, unconfined compression test one dimensional consolidation test and triaxial shear test (un-consolidation, un-drained, consolidation- un-drained test with measurement of pore water pressure, consolidated drained) laboratory test to performed on undisturbed soil sample. Visual classification water- absorption slope durability, porosity and density, unconfirmed compression test (Both at saturated and in situ water-contest), rock modulus of elasticity and Poisson's ration, Brazilian tensile-strength and point load-strength index laboratory test to be performed on rock samples. Submission of all test reports along with safe bearing capacity of Soil at different levels- in triplicate. | 45.00 | Mtr |
| 2 | Providing consultancy for structural analysis and design for RCC framed structure with design of M S Tubular truss including purlins etc, which includes structural design philosophy, Structural design and preparation of working structural drawings with full structural detailing of all structural members i.e foundation/ footings columns beams and other joinery details etc including submission of input data, analysis, BOQ (as per latest DSR) and design data, including structural drawings 4 nos (Al size). set of all structural drawing, along with soft copy and 30 detail architectural including single line diagram electrical wiring and installation (Interior & Exterior) of design will be handed over to the department as per direction of Engineering-In- Charge. The structural drawing/ design shall be got vetted from any IIT/NIT or Govt Engineering college as approved by Engineer-In-Charge and vetted charges shall have to be pay/ attended by consultant. However, consultant has to properly coordinate with the Institute to get the design drawings vetted. Any charges/ corrections asked by Institute shall have also to be attended by the consultant till final drawings for construction duly vetted by institute are not issued. | 961.96 | Sqm |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054