- Home
- >
- Tender
- >
- Uttar Pradesh Tender
- >
- Department of SASHASTRA SEEMA BAL
- >
NTID 43233155
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowAnnual Repair And Maintenance in LAKHIMPUR KHIRI - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Annual Repair And Maintenance " in LAKHIMPUR KHIRI, India.
SASHASTRA SEEMA BAL
LAKHIMPUR KHIRI, Uttar Pradesh, India
NTID 43233155
- Opening Date : Fri 26th December, 2025
- Closing Date : Thu 25th December, 2025
- ₹ 2496219.00
- NTID 43233155
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
49924.00 -
Document Cost
Refer Documents -
Estimated Cost
2496219.00
BOQ Items Total Items : 40 | Total Qty : 1494
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Annual Comprehensive Preventive maintenance of 3Nos HT 33 KV, VCB Breaker, Panel 630 Amp with all accessories ABB make & 2 Nos 1600 KVA 33/0.433 KV ONAN Transformer Kirloskar make I/c minimum one visit in a month by OEM Engineer attending complaints for rectification of defects during any breakdown with in 12 Hrs of its occurance or as and when required i/c testing & other works for routine periodic preventive maintenance atleast after every months as per checked list below through authoriszed service centre of Kirloskar make transformers (02Nos) & ABB make HT Panel/VCB Breakers (03Nos) (A) Complete servicing (Twice in a year or as per direction of Engineer-in-charge) | ||
| 2 | (1) Complete relay testing mounted in HTVCB panels and transformers i/c chekcing of tripping system (2) Mechanical adjustment of breakers (3) Checking of T&C switch operation tesing (4) Checking of all hardware for its tightneess for all equipments (5) Busbar tightness (6) Checked of all WTI & oil temperature indoor system other safeties (7) Checking of all controlling circuit/equipment make in order (8) Cleaning of transformers & HTVCB panel and OLTC panel etc (9) complete Servicing of transformers (10) In case traansformer unserviciable, repair by new copper winding. (10) Remove of dust particles (11) Checking of voltage ratio test (12) Checking of insulation resistance test [HV to Body; LV to Body & HV to LV ] (13) Checking of MBT (14) Checking of vector group test (15) Checking of WTI/OTI scanner programming & servicing etc i/c servicing of relay | ||
| 3 | (16) Servicing,repair, gressing, testing and calibration of OLTC Panel (17) Testing checking and making it in order of transformers, OLTC, HT VCB Panels, Meters & other equipments (18) Any all other activities related to preventive maintenance of ONAN type transformer, OLTC & 33 KV HT VCB Panel.as per instruction of Engineer Incharge i/c complete repair & testing of svstem (19) Supply/replacement of all type of major/minor spare parts ,disassembling , complete cleaning of the components, decarbonizing the arcing chambers, rewinding of transformer coils, replacement of core,relay, indication lamp,CT,PT, control wiring,replacement of unserviciable Batteries, charger etc (B) Work mandatory during every periodic check every month or and as when required keeping the whole HT system in order | ||
| 4 | (1) During monthly preventive maintenance visits which includes cleaning of VCB Breaker, servicing of complete VCB breaker, removal of dust, checking of all hardwares for its tightness, checking of OC/EF primary injection test, checking/Testing of insulation resistance test, checking of CRM testing, Checking of secondary injection test, Checking of Timing testing, scanner programming and servicing etc., (2) During monthly preventive maintenance visits complete checking of the 1600 KVA, 33 KV/.433 kV transformers for oil leakages, holes in the radiator fins, flapper valve packings, top cover plates, threaded fittings, flapper flanges, radiator flanges, electrical bushing leaks, and stopping leakage by providing necessary sealants, gaskets, rubber washers, chemical cleaning agents, or any other consumables, including the opening of the top cover and draining out the oil to repair leakage (if required), to ensure zero leakage, etc. and complete cleaning of outer surface the transformer as required. | ||
| 5 | (C). Dehydration and filtration (once in a year) of transformer oil by high vacuum machine, in transformers of 1600 KVA, 33 KV/.433 kV, ratings to free the oil from any impurities, sludge and moisture to get the desired level of BDV value as per relevant IS standard, including breakdown Voltage strength test before and after dehydration at site including submission of test report complete etc. as required. [All necessary tools, machinery spares, consumables excluding transformer oil required for top up , to be provided by the contractor. Note:The work will be done through the OEM or OEM-authorized dealer. All consumables & defective parts of VCB & Transformer during maintenance period will be replaced with OEM genuine parts by agency free of cost, rates are inclusive. | 12.000 | Month |